Li2YCYv (twisted pair)

Screened data transmission cable mit PE core insulation, reinforced outer sheath and twisted pairs; Li2YCYv (TP): Low-capacitance screened PVC data cable, DIN 47100 coded Twisted PE pairs, Reinforced black jacket/ Outdoor laying, RS422/ RS485 wiring

STRUCTURE & SPECIFICATION

conductor material bare copper strand
conductor class 7 wired
core material PE
core identification acc. to DIN 47100 different colours
stranding pairs stranded in layers
shield copper braid tinned; coverage approx. 85%
outer sheath PVC
sheath colour  black, RAL 9005 (CYv)
rated voltage 250 V
testing voltage core/core: 2 kV; core/shield: 1 kV
conductor resistance loop: 0,22 mm² max. 186 Ω / km; 0,34 mm² max. 115 Ω / km; 0,50 mm² max. 78,4 Ω / km
insulation resistance min 5 GΩ x km
current carrying capacity acc. to DIN VDE, s. Techn. Guidelines
capacity max. 60 nF/km (from 4 pairs)
min. bending radius fixed 10 x d
min. bending radius moved 15 x d
operat. temp. fixed min/max -30 °C / +80 °C
operat. temp. moved min/max -5 °C / +70 °C
burning behavior flame-retardant acc. to IEC 60332-1-2
standard similar to DIN VDE 0812