NSGAFÖU 1.8/3 kV / NSGAFOU 1.8/3kV
Rubber Cables / NSGAFÖU 1.8/3 kV / NSGAFOU 1.8/3kV

NSGAFÖU 1.8/3 kV / NSGAFOU 1.8/3kV
This wire is designed for use in dry rooms, buses and rail-borne vehicles. It is considered to be short circuit-proof and earth leakage-proof when used in switching appliances and distributors of up to 1 kV. It is flame-retardant and resistant to most oils.
STRUCTURE & SPECIFICATION
Customs Tariff Number (code number) | 85446010000000000 |
CPR-performance | Eca |
Standard | VDE 0250 T. 602 |
Conductor material | tinned copper |
Conductor class | class 5 = fine stranded |
Insulation | rubber (EPR) 3GI3 |
Sheathing material | rubber (CR) 5GM5 |
Flame-retardant | VDE 0482-332-1-2/IEC 60332-1-2 |
Oil-resistant | yes |
Ozone-resistant | yes |
Maximum permitted conductor temperature, °C | 90 °C |
Permitted outer cable temperature, fixed, °C | -40 - +80 °C |
Permitted outer cable temperature, in motion/during installation, °C | -25 - +80 °C |
Number of cores | 1 |
Colour of outer sheath |
black |